BKQBJ - TEFLON TOPCOATS (455-201)

Product Identification

Product ID:TEFLON TOPCOATS (455-201)
MSDS Date:01/01/1987
FSC:8010
NIIN:00N015354
MSDS Number: BKQBJ

Responsible Party
E I DUPONT DE NEMOURS & CO
1007 MARKET STREET
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)

Info Phone: 800-441-7515

Cage: 0ERJ7

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

PARTICULARLY SENSITIVE TO DMG BY HF & ATTN MUST BE

RTECS: 9999999ZZ


METALS REPORTED IN INGREDIENTS SECTION, IF ANY. EYE

RTECS: 9999999ZZ


5

CAS: 64742-95-6


OCTYLPHENOXYPOLYETHOXYETHANOL (NON-IONIC SURFACTANT)


TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


MICA - SILICATES (< 1% CRYSTALLINE SILICA)

CAS: 12001-26-2

RTECS: VV8760000

OSHA PEL 20 MPPCF

ACGIH TLV: 3 MG/M3 RDUST; 9293


CONSCIOUSNESS. CAUSES EYE CORR & PERM

RTECS: 9999999ZZ


IRRIT. RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT &

RTECS: 9999999ZZ


NAUS & LOSS OF CONSCIOUSNESS. RPTS HAVE ASSOC RPTD &

RTECS: 9999999ZZ


DMG. (ING 5) CONT MAY CAUSE SKIN IRRIT

RTECS: 9999999ZZ


KNOWN HAZ W/NORMAL INDUSTRIAL USE. IN A LIFETIME

RTECS: 9999999ZZ


EXPOSED TO 250 MG/M3 RESP TDUST. ANALYSIS OF

RTECS: 9999999ZZ


CLEARANCE MECHANISM WAS OVERWHELMED & THE RESULTS

RTECS: 9999999ZZ


THE WORKPLACE. (ING 7) RPTD & PRLNGD OVEREXP MAY

RTECS: 9999999ZZ


TEMPS. BAKING OVENS MUST BE PROPERLY VENT. AT TEMPS

RTECS: 9999999ZZ


CAN BE EVOLVED; AMTS INCR AS TEMP INCR. HYDROGEN

RTECS: 9999999ZZ


(3 PPM CEILING-ACGIH). HIGH CONC CAN CAUSE LUNG

RTECS: 9999999ZZ


FLUOROPOLYMER SOLIDS


0.01

CAS: 112-34-5

RTECS: KJ9100000


0.01

CAS: 102-71-6

RTECS: KL9275000

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHAL: NORMALLY NOT A HAZ. THESE PRODS
CONTAIN SM AMTS OF SOLV AS DESCRIBED BELOW. SKIN/EYE: MAY CAUSE
IRRIT/BURNING OF EYES. RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT
W/DISCOMFORT & DERMAT. OTHER POT ENTIAL HAZ INCL: (ING 1) SEE HAZ
DECOMPPRODS. (ING 2) MAY CAUSE EYE IRRIT W/DISCOMFORT, TEARING (SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:CRYSTALLINE, SILICA: IARC-2A
Effects of Overexposure:HLTH HAZ: OR BLURRED VISION. CONT MAY CAUSE
SKIN IRRIT W/DISCOMFORT/RASH. CAN BE ABSORBED THRU SKIN IN HARMFUL
AMTS. MAY CAUSE ABNORMAL KIDNEY FUNC. (ING 3) OVEREXP MAY CAUSE
EYE, NOSE & THROAT IRRIT. RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN
IRRIT & DERMAT. MAY CAUSE CNS EFTS SUCH AS DIZZ, HDCH, NAUS & LOSS
OF (SEE ING 8)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: IF AFFECTED BY INHAL OF VAP/SPRAY MIST, REMOVE TO
FRESH AIR. IF NOT BRTHG, GIVE ARTF RESP, PREF MOUTH-TO-MOUTH. IF
BRTHG DIFFICULTY PERSISTS/OCCURS LATER, CALL MD. SKIN/EYE: EYE:
IMMED FLUSH W/ PLENTY OF WATER FOR AT LEAST 15 MIN; CALL MD. SKIN:
WASH W/SOAP & WATER. IF IRRIT OCCURS, CALL MD. INGEST: GI DISTRESS.
IN UNLIKELY EVENT OF INGEST, CALL MD IMMED & HAVE NAMES OF INGRED
AVAIL.

Fire Fighting

Flash Point:NONE
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL PROT
EQUIP . WATER FROM FOG NOZZLES MAY BE USED TO COOL CLSD CNTNRS TO
PVNT PRESS BUILD-UP.
Unusual Fire/Explosion Hazard:HYDROGEN FLUORIDE IS RELEASED DURING A
FIRE.

Accidental Release

Spill Release Procedures:VENT AREA. REMOVE SOURCES OF IGNITION. AVOID
SKIN CONTACT & BREATHING OF VAPOR. CONFINE AND REMOVE WITH INERT
ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OBSERVE LABEL PREC. KEEP AWAY FROM
HEAT, SPARKS & FLAME. CLOSE CNTNR AFTER EACH USE. GROUND CNTNRS
WHEN POURING. DO NOT STORE ABOVE 120F.
Other Precautions:EXPLOS RXN MAY OCCUR ABOVE 796F W/FINELY DIVIDED
FLUOROCARBON AND METAL POWDER (ALUMINUM/MAGNESIUM). OPERATIONS SUCH
AS GRINDING, BUFFING OR GRIT BLASTING MAY GENERATE SUCH MIXTURES.
KEEP WET. USE ADE QUATE VENTILATION TO CONTROL.

Exposure Controls

Respiratory Protection:DO NOT BREATHE VAPS/MISTS. WEAR A PROPERLY
FITTED NIOSH/MSHA APPRVD RESPIRATOR FOR USE WITH PAINTS DURING
APPLICATN & UNTIL ALL VAPS & SPRAY MIST ARE EXHAUSTED. FOLLOW THE
RESP MFR DIRECTIONS FOR RESP USE.
Ventilation:PROVIDE SUFFICIENT VENT IN VOLUME & PATTERN TO KEEP
CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEM WORKERS GOGG.MAY ADD(SEE INGRED-20)
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING AND SMOKING.
Supplemental Safety and Health
% VOLAT: 46.3-49.1 (WT). HAZ DECOMP PRODS: THESE SYMP DO NOT ORDINARILY
OCCUR UNTIL SEV HRS AFTER EXPOS & PASS WITHIN 36-48 HRS. EFTS ARE
NOT CUMULATIVE. EXPOS USUALLY RESULTS FROM SMOKING TOBACCO/CIG
ARETTES CONTAM W/FLUOROCARBON DURING HANDLING/FROM BRTHG VAPS
EMITTED DURING BAKING. DO NOT EXCEED REC (SEE ING 15)

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:APPRECIABLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:EXPOS TO TEFLON DECOMP PRODS CAN
CREATE INFLUENZA-LIKE SYMP, COMMONLY REFERRED TO AS POLYMER FUME
FEVER. (SEE SUPP DATA)

Disposal

Waste Disposal Methods:DO NOT ALLOW MATL TO CONTAM GROUND WATER
SYSTEMS. SEND TO HAZ WASTE WATER TREATMENT PLANT/INCINERATE
ABSORBED MATL IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
REQUIREMENTS. DO NOT INCINERATE IN CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.